Pump Conversion for Gravity Feed- 1500 psi
- Standard 1500psi pump has built-in filter and solenoid.
- To convert 1500 psi pump for gravity feed operation, open the pump enclosure from mentioning “OPEN THIS SIDE FOR MAINTAINENCE”.
- Remove solenoid (2) and by-pass the pressure switch (3); to bypass the pressure switch, simply remove the two wires that are currently on it and loop them together. Pump will now turn on even at 0psi inlet water pressure.
- Take off the filter from feed line and place it ahead of water tank or reservoir to fill it with clean water.